. Changing the gas control valve is not as difficult as you assume. You may need to install Adobe Acrobat Reader to view these documents. Now, turn the electric power on to your water heater. Otherwise, the status light wont blink. Revision 3 includes updated troubleshooting for error codes 4 and 6 and technical bulletins, Manual will be automatically added to "My Manuals", Error Code 3 - Pressure Switch Circuit Remains Closed, Error Code 4 - Pressure Switch Circuit Remains Open, Error Code 7,8,9 - Internal Control Failures, Error Code 10 - Flame Sensed out of Sequence, Error Code 11 - High Temperature Cutoff (Eco) Activated, Error Code 12 - Temperature Adjust Buttons Stuck Closed, Error Code 13 - Temperature Probe Open of Shorted, Error Code 14 - Resistor Wire Open or Shorted, Error Code 15 - Resistor Wire Resistance out of Tolerance, Technical Bulletin - Ignition and Flame Failure A-022-04 & S-021-04 Combined, Air Pressure Switch Circuit - Residential Power Vent/Power Direct Vent, Vent Termination Restrictor Usage for 40,000 Btu Power Vent Models, TB-A028-06 - A. O. Smith - FVIR Intelli-Vent Troubleshooting Chart, Normal Operating Sequence - Pressure Switch Circuit, Air Pressure Switch Circuit: Residential Power-Vent & Power-Direct-Vent Water Heaters, Air Pressure Switch Circuit: Cyclone Water Heater. The reason behind this is that the heater does not get enough water to heat up properly causing an imbalance in temperature. Error code 441 (LED flashes two times) Problem: Flow sensor. Other uncategorized cookies are those that are being analyzed and have not been classified into a category as yet. Pentair Heater E05 Error Code [Reasons + Solutions]. You can read this article on Rheem Water Heater Leaking. So, check out the section again. Performance cookies are used to understand and analyze the key performance indexes of the website which helps in delivering a better user experience for the visitors. Check the gas valve and make sure that it is turned on completely. To fix this issue, you should replace the control board. If your AO Smith Electric Tankless Water Heater throws the error code E51 or E52, understand the user interface lost its connection with the control board. Get information and support for all A. O. Smith models. GCVL40-200 GCVL40-201 GNR40100 GNR50100 GPS-75 GPVH40100. Then, watch this tutorial and follow the steps to get the temperature sensor replaced: If you observe the status light of your water heater flashes 7 times consecutively with a three-second pause, understand the gas valve is at fault. If you dont know how to replace the sensor, call a professional for the replacement. Functional cookies help to perform certain functionalities like sharing the content of the website on social media platforms, collect feedbacks, and other third-party features. Problem: Problem with the computer board. Just turn on a hot water faucet and let the water run for several minutes. Higher temperatures increase the risk of scalding, but even at 120F, hot water can Throughout this article, I will disclose the meaning of the error codes your AO Smith Electric Water Heater throws. A thin or low flow of water to or from the water heater can also cause the e05 on Pentair heater display. FIX: Debris on the thermistor, loose or broken wire connection. Then, ensure you have the following pieces of equipment at your fingertips: Secondly, check the user manual and drain the water heater by following the instructions. If you install the unit professionally and maintain it according to the manual, it will support you for up to 10 years. Ensure you shut off the electric supply to your water heater. Also, you should check the computer board for any sign of burn marks too. Bathtub faucets typically have a flow rate of 5 Gallons per Minute. CODE: 651, Four timesPROBLEM: Flow adjustment valve fault. Then, shut off the main gas supply valve. No problems with the new one, plus it was much cheaper and lowes gave me a credit for the old one, not just a straight replacement, so I ended up with a lowes gift card for the difference. The consent submitted will only be used for data processing originating from this website. Pentair heater error codes are ERR PS, ERR HLS, ERR AFS, ERR IGN, ERR AGS, ERR SFS, E01, E05, and E06. Solution: Connections or wire breakage of the flow adjustment valve, scale buildup on the motor drive that gets locked, or there is water leakage. COPYRIGHT 2023. Eric Alvarez is an HVAC guy based in El Paso, Texas, United States. Now, back the electric power to your water heater and it will clear those faulty codes. how to fix the Pentair heater error codes problem, Rheem Tankless Water Heater Maintenance [Why+ How To Do], Rheem Tankless Water Heater Code 61 [Why+ How To Fix], Rheem Tankless Water Heater Code 14 [Why+ How To Fix], Rheem Tankless Water Heater Code 99 [Why+ How To Fix], Rheem Tankless Water Heater Code 76 [Why+ How To Fix]. Jenn-Air JGS8750ADB Control Panel Burning Hot! It will be best to consult with a certified professional or the technical support team. While it may be igniting, its not keeping its flame and is going out before it can adequately warm up your water. Tanks, iCOMM Smart Connectivity allows you to get notifications and manage your water heater from your smartphone. So not happy that I had to replace it, but very happy with AO Smith that they honored the warranty. This represents our closest approximation of your likely experience with this water heater using National Averages, but actual performance may vary depending on factors beyond our ability With power turned off to the heater replace the upper element. Solution: Check the wire connection, wire breakage, and debris on the flow sensor impeller. He obtained his Bachelor of Science degree from the University Of Texas at El Paso. The thin flow of water is typically a result of scaled-up pipes or improper water pressure. Its important to note that the error codes we will be addressing in this guide are found on the 110, 510, 310, 240, 240 and 540 AO Smith tankless water heater models. We will also tell you the solutions that will help you to fix the problem. See how to troubleshoot the flame failure, not enough, no hot water . So, replace the sensor to clear the faulty code. We don't tend to provide any plumbing advice or any advice that should come from a certified professional. Malfunctioning Control Board 4. CODE: 341, Two timesPROBLEM: Exhaust thermistor failure. These cookies track visitors across websites and collect information to provide customized ads. The cookie is used to store the user consent for the cookies in the category "Analytics". Use the pipe wrench to tighten the fittings. Once this problem occurs, the main burner will go into the off position along the pilot light immediately. Finally, turn the power back to the unit and it will clear the error code. Smith Water Heater, look no further! Smith Water Heater Error Codes. Although the early symptoms are dizziness or a headache, death may be the final result if they cannot get the proper treatment. Fixing the error as soon as it appears is important for the performance and longevity of the pool heater. Your AO Smith Water Heater wont light up if there are electrical problems like the thermopile wires come loose. Problem: Bypass valve fault (only model 540). Less things to go wrong. The Pentair error code E05 indicates an open stack flue sensor. If you own a 540 model AO Smith tankless water heater, then this is an error code that may appear on your display screen. Smith water heater? In this case, you must flush the unit. Examine the thermal regulator to see whether it is offering a proper performance or not. From https://www.justanswer.com/ythiJustAnswer Customer from San Antonio, TX: AO Smith 50 gallon electric water heater giving error code e55 for water leak d. FIX: Check for blockage in the vents, the distance between the intake and exhaust terminals are per instructions and remove if there is grease or dirt in the gas burner and fan motor. Besides, I will also walk you through the troubleshooting steps to clear those error messages. You should consult with a licensed professional and check local permit requirements before starting any project. on: function(evt, cb) { Now, press the red button to reset the unit successfully. CODE: 61, 611, Four timesPROBLEM: Fan motor fault. Scale is caused by water settling on heat transfer surfaces and the impurities build up into a hard, crusty layer. Spray it on the gas connections (you can also apply the mixture with the sponge or paintbrush). FIX: Is the water heater set for the right elevation? What causes water hammer in a house and what makes pipes to vibrate and make banging, ticking and popping sound? Just shut off the electric supply to the unit. 4.6. Necessary cookies are absolutely essential for the website to function properly. Thirdly, locate the thermistor on your water heater. These are The Easy Steps, The sound of the door squeaking is certainly very, You may want to remove broken drills from wood when, Spray paint is an aerosol paint that is used by, The toilet flange heightis important for proper, After you receive your new washing machine, you are, Most people take it for granted that their, Like most people, you probably take your air, Copyright 2022 Burnshomeconstruction.com. Main Menu. An example of data being processed may be a unique identifier stored in a cookie. I am gettin tempure sensor failure code (#5) what should I be replacing. JavaScript is disabled. Scale build up could be the cause of locking the motor drive and is usually caused by a water leak somewhere within your water heater. To solve & clear the error message, turn the power off to your water heater first. There could be an issue with the power supply of your water heater and thus it could be failing. So, whenever the error code pops up on the heater display, fix it with the help of our guide by yourself. CODE: 661, Four timesPROBLEM: Bypass valve fault (only model 540). Open the control panel and make sure that the stack flue sensor is working properly. The flame rod should be free from dirt and grease, and the computer board should not be damaged. Basically, both 2-chamber and 4-chamber models will pop up with those error codes. See Figure 4. forms: { You are using an out of date browser. {{INUSING}}, The average cost per Mcf is ${{NATURALGASPRICE}} Use the search box below to quickly find your model number. Note: You can also read how to fix the Pentair heater error codes problem. Legal Disclosure:Lildutchuncle.com provides and shares information on plumbing, heating & air quality, home improvement, and other DIY projects. See the symptoms of How to fix water hammer problem in pipes. Is there leaking from the heat exchanger? We and our partners use data for Personalised ads and content, ad and content measurement, audience insights and product development. This problem occurs because of two reasons. Tankless water heater problems and how to repair models from Noritz, Rinnai, Takagi using error codes. AO Smith Water Heater Troubleshooting Lights [8 Common Blinking Light Codes]. The Water Heater Settings Hot, A, B, C, Very Hot Knob. Then, find the source of the water leak. He said it appeared the thin wires for the smart module had burned out from the plastic connector. Can you hear a buzzing spark ignition from the burner or two clunk sounds from the gas valve? Gas water heater using too much gas. You can see the flash code once you relight the pilot light. Our comprehensive A.O. Second, turn on a hot water faucet anywhere in your house to let the air out of the waterline. window.mc4wp.listeners.push( Take out the thermal regulator and replace it with a new one. Another sign that you are facing the same problem would be if the LED light is blinking once. The initial setting is 120F, but you're in control after installation. And this guide on AO Smith Water Heater Troubleshooting Lights broke down everything you need to know. If the remote controller is not installed on the water heater, and there is a problem, the error codes will be shown differently. compare. Hi, I have an AO Smith GCVL 40 300 natural gas with a Honeywell valve. ], Bosch Tankless Water Heater Maintenance [The Complete Guide], Bosch Tankless Water Heater Troubleshooting [A Complete Guide], Bosch Tankless Water Heater Error Codes [Ultimate Guide], Bosch Tankless Water Heater Wont Ignite [7 Easy Solutions]. AO Smith Water Heater Error Code E02 [5 Easy Fixes] 1. Continue with Recommended Cookies. For example, a bad thermostat, a bad computer board, and burn-out connectors that lead to the computer module are responsible for producing too much hot water. We don't tend to provide any plumbing advice or any advice that should come from a certified professional. Advertisement cookies are used to provide visitors with relevant ads and marketing campaigns. e. They should be able to tell you the correct dipswitch settings for your model so you can correct it yourself. Alternatively, you can watch this video that will come in handy: AO Smith Water Heater Status Light will flash 8 times every 3 seconds if the gas control valve is in the off position but the thermopile still produces electric power. Error Code 61, 611, Four times Problem: Fan motor fault. Common symptoms, problems, and fixing tips. You can easily detect the exact problem of your water heater if you know the meaning of the flashing light code. Double check with your water heaters manual first and if everything seems to be fine, then you need to call out a technician. Learn about AO Smith tankless error codes for easy and inexpensive troubleshooting. Water Heaters. All of the above error codes all point to the same problem: an issue with your gas solenoid valve. 12-Year limited residential warranty gives you peace of mind. This final error code indicates that there is a false flame being detected within your water heater. I This is the error code for ignition failure.